49 lines
2.6 KiB
INI
49 lines
2.6 KiB
INI
[z_calibration]
|
|
nozzle_xy_position: 228,346
|
|
# A X, Y coordinate (e.g. 100,100) of the nozzle, clicking on the z endstop.
|
|
switch_xy_position: 222,325
|
|
# A X, Y coordinate (e.g. 100,100) of the probe's switch body, clicking on
|
|
# the z endstop.
|
|
#switch_xy_offsets: optional when switch_xy_position is used
|
|
# Instead of an absolute position (switch_xy_position), this configuration
|
|
# adds an X, Y offset (e.g. -6,-18) to the nozzle position.
|
|
bed_xy_position: 175,175
|
|
# A X, Y coordinate (e.g. 100,100) where the print surface (e.g. the center
|
|
# point) is probed. These coordinates are adjusted by the
|
|
# probe's X and Y offsets. The default is the zero_reference_position which
|
|
# replaces the deprecated relative_reference_index
|
|
# of the configured bed_mesh, if configured. It's possible to change the zero
|
|
# reference position at runtime or use the GCode argument BED_POSITION of CALIBRATE_Z.
|
|
wiggle_xy_offsets: 0,0
|
|
# After probing the nozzle and retracting, move x some distance away and
|
|
# back. Useful to prevent the z endstop pin sticking to the nozzle and
|
|
# being pulled out of the assembly. Can be negative. Defaults to zero to
|
|
# disable it. Can be combined in x and y to move diagonally. Be careful
|
|
# to not move your nozzle out of range!
|
|
switch_offset: 0.521
|
|
# The trigger point offset of the used mag-probe switch.
|
|
# A larger value will position the nozzle closer to the bed.
|
|
# This must be determined manually. More on this later
|
|
# in this section..
|
|
offset_margins: -1.0,1.0
|
|
# The minimum and maximum margins allowed for the calculated offset.
|
|
# If the offset is outside these values, it will stop!
|
|
# The margin can be defined as "min,max" e.g. "-0.5,1.5" or by just one
|
|
# value e.g. "1.0" which translates to "-1.0,1.0" (which is also the default).
|
|
probing_first_fast: false
|
|
# If true, the first probing will be faster by the probing speed.
|
|
# This is to get down faster and not record the result as a
|
|
# probing sample. The default is false.
|
|
start_gcode: ATTACH_PROBE
|
|
# A list of G-Code commands to run before each calibration command.
|
|
# See docs/Command_Templates.md for the G-Code format. This can be used to
|
|
# attach the probe.
|
|
#before_switch_gcode:
|
|
# A list of G-Code commands to run before to each probing on the
|
|
# mag-probe. See docs/Command_Templates.md for the G-Code format. This can
|
|
# be used to attach the probe after probing on the nozzle and before probing
|
|
# on the mag-probe.
|
|
end_gcode: DOCK_PROBE
|
|
# A list of G-Code commands to run after each calibration command.
|
|
# See docs/Command_Templates.md for the G-Code format. This can be used to
|
|
# detach the probe afterwards.
|