[z_calibration] nozzle_xy_position: 228,346 # A X, Y coordinate (e.g. 100,100) of the nozzle, clicking on the z endstop. switch_xy_position: 222,325 # A X, Y coordinate (e.g. 100,100) of the probe's switch body, clicking on # the z endstop. #switch_xy_offsets: optional when switch_xy_position is used # Instead of an absolute position (switch_xy_position), this configuration # adds an X, Y offset (e.g. -6,-18) to the nozzle position. bed_xy_position: 175,175 # A X, Y coordinate (e.g. 100,100) where the print surface (e.g. the center # point) is probed. These coordinates are adjusted by the # probe's X and Y offsets. The default is the zero_reference_position which # replaces the deprecated relative_reference_index # of the configured bed_mesh, if configured. It's possible to change the zero # reference position at runtime or use the GCode argument BED_POSITION of CALIBRATE_Z. wiggle_xy_offsets: 0,0 # After probing the nozzle and retracting, move x some distance away and # back. Useful to prevent the z endstop pin sticking to the nozzle and # being pulled out of the assembly. Can be negative. Defaults to zero to # disable it. Can be combined in x and y to move diagonally. Be careful # to not move your nozzle out of range! switch_offset: 0.521 # The trigger point offset of the used mag-probe switch. # A larger value will position the nozzle closer to the bed. # This must be determined manually. More on this later # in this section.. offset_margins: -1.0,1.0 # The minimum and maximum margins allowed for the calculated offset. # If the offset is outside these values, it will stop! # The margin can be defined as "min,max" e.g. "-0.5,1.5" or by just one # value e.g. "1.0" which translates to "-1.0,1.0" (which is also the default). probing_first_fast: false # If true, the first probing will be faster by the probing speed. # This is to get down faster and not record the result as a # probing sample. The default is false. start_gcode: ATTACH_PROBE # A list of G-Code commands to run before each calibration command. # See docs/Command_Templates.md for the G-Code format. This can be used to # attach the probe. #before_switch_gcode: # A list of G-Code commands to run before to each probing on the # mag-probe. See docs/Command_Templates.md for the G-Code format. This can # be used to attach the probe after probing on the nozzle and before probing # on the mag-probe. end_gcode: DOCK_PROBE # A list of G-Code commands to run after each calibration command. # See docs/Command_Templates.md for the G-Code format. This can be used to # detach the probe afterwards.